- 8 -
PDM Installation
Pressure Module Defaults
Keys command:
1. Press “SET” to select
2. Press return key move to next operation mode
3. Up/Down arrow keys to adjust value or select type
Main Screen: SP = 80% of span
Press return key and release
Operation
Mode
Select type/value Comment
r-S Run Run/Stop
SP to be determined** Decimal point position
AL1H 0 Upper-limit alarm 1
LoC OFF Lock mode(lock all keys or only up/down arrow
able to use)
** If units are psi, SP = 0
If units are Bar, SP = 1
If units are MPa, SP = 2
Vedere la pagina 7